The Schumacher FR01337 Jump Starter and DC Power Source is a portable power station designed for jump-starting vehicles with 12V battery systems, powering compatible electrical devices, inflating tires, and providing work or emergency lighting. The Farm & Ranch portable power unit combines a 1200 peak amp jump starter, a 12V DC power outlet, a built-in AC power converter, four USB ports, a 100 PSI air compressor, and a flexible work light.

The FR01337 contains a sealed, maintenance-free AGM lead-acid battery. Its digital display shows the internal battery charge percentage and vehicle battery voltage during jump-starting operations.

The unit supports 12V vehicle battery systems and provides portable electrical power through its USB, DC, and AC outlets. Proper charging, battery clamp connections, operating limits, and regular maintenance are essential for safe operation.

Product Features

The Schumacher FR01337 includes the following features:

  • 1200 peak amp jump-starting capability.
  • Support for vehicles with 12V DC battery systems.
  • Sealed, maintenance-free AGM lead-acid internal battery.
  • Digital display with internal battery charge percentage.
  • Vehicle battery voltage display.
  • Reverse-polarity audio warning.
  • Four USB charging ports with 5V DC output.
  • 12V DC accessory power outlet rated at 20A.
  • Built-in AC power converter with 200W continuous output and 400W peak output.
  • Modified sine wave AC power output.
  • Built-in air compressor rated for a maximum of 100 PSI.
  • Adjustable compressor pressure with automatic shutoff.
  • Flexible LED work and emergency light.
  • Internal battery charging through a 120V AC connection.
  • Optional charging through a vehicle’s 12V accessory outlet using a separate charging cable.
  • Automatic battery maintenance during AC charging.
  • Compressor overheat protection.
  • Portable power for compatible electrical accessories.

Technical Specifications

SpecificationDetails
BrandSchumacher Electric
Product LineFarm & Ranch
Model NumberFR01337
Product TypeJump Starter and DC Power Source
Internal Battery TypeSealed, Maintenance-Free AGM Lead-Acid
Internal Battery Voltage12V DC
Peak Starting Current1200A
DC Power Output12V DC, 20A
AC Converter Output120V AC, 60Hz
Continuous AC Power200W
Peak AC Power400W
AC Converter WaveformModified Sine Wave
AC Outlet Type3-Prong NEMA 5-15
USB Ports4
USB Output Voltage5V DC
USB Current2A Per Side, 4A Total
Air Compressor Maximum Pressure100 PSI
Maximum Continuous Compressor Operation10 Minutes
Compressor Cooling Time10 Minutes
Internal Battery Charging Input120V AC
Maximum Internal Battery Charging TimeUp to 72 Hours
Jump Starter Warranty1-Year Limited Warranty
Internal Battery Warranty90 Days

Parts and Components

The Schumacher FR01337 includes several operating controls and electrical connections.

Main Parts and Controls

No.ComponentFunction
1USB Ports Optimized for Android (2)Supply USB power to compatible devices
2Pressure Decrease (–) ButtonReduces the selected compressor pressure
3Pressure Increase (+) ButtonIncreases the selected compressor pressure
4Set Pressure ButtonConfirms the selected compressor pressure
5Compressor Mode ButtonActivates the air compressor controls
6Flex LightProvides work and emergency lighting
7Digital DisplayShows battery information and operating values
8Display LED IndicatorsIndicate selected functions and operating status
9Converter ButtonActivates the AC power converter
10USB ButtonTurns USB power output on or off
11Battery % ButtonDisplays the internal battery charge percentage
12Flex Light ON/OFF ButtonControls the work and emergency light
13USB Ports Optimized for Apple (2)Supply USB power to compatible devices
14Battery Cables with ClampsConnect the jump starter to a vehicle battery
15AC Household Power OutletSupplies power to compatible AC devices
16Jump Starter ON/OFF SwitchEnables or disables jump-starting output
1712V DC Power OutletSupplies power to compatible 12V accessories
18Air Compressor HoseConnects the compressor to an inflation valve
19Inflation AdaptersConnect the compressor hose to compatible inflatable items

Control Panel and Digital Display Guide

The FR01337 uses a digital display and dedicated buttons for battery monitoring, jump-starting, USB power, inflation, lighting, and AC power.

Battery % Button

The Battery % button displays the charge remaining in the internal battery.

When the button is pressed, the digital display shows the battery’s charge percentage.

The internal battery should be recharged if the display indicates less than 100%.

The battery percentage reading is most accurate after the unit has been disconnected from electrical devices and charging sources for several hours.

Jump Starter ON/OFF Switch

The Jump Starter ON/OFF switch controls the jump-starting function.

The switch must remain OFF while the battery clamps are being connected.

After correct connections have been made, the switch can be turned ON to begin jump-starting.

Converter Button

The Converter button activates the built-in AC power converter for powering compatible AC electrical devices.

USB Button

The USB button activates and deactivates the four USB charging ports.

Compressor Button

The Compressor button activates the air compressor control system.

The + and – buttons adjust the selected pressure, while the SET button confirms the pressure setting.

Flex Light Button

The Flex Light button controls the work and emergency light.

The light has three operating states:

Button OperationLight Behavior
First PressLight turns on
Second PressLight flashes
Third PressLight turns off

Digital Display During Jump-Starting

Operating ConditionDisplay Information
Battery % Button PressedInternal battery charge percentage
Connected to Vehicle, Jump Starter OFFVehicle battery voltage
Connected to Vehicle, Jump Starter ONEqualized voltage between the vehicle battery and internal battery
AC Charging in ProgressMoving dashes
Internal Battery Fully ChargedSmall pulsing ioo display
Converter Faulterr

Important Safety Instructions

WARNING: Risk of explosive gases, electric shock, fire, and serious personal injury.

Lead-acid batteries produce explosive gases during normal operation. Proper precautions must be followed whenever the FR01337 is connected to a vehicle battery.

General Safety Precautions

  • Keep the portable power unit away from children.
  • Do not disassemble the unit.
  • Have maintenance and repairs performed by qualified service personnel.
  • Do not operate the unit if it is damaged.
  • Do not expose the unit to rain or snow.
  • Do not recharge the unit with a damaged extension cord.
  • Do not place the unit on flammable materials such as carpeting, upholstery, paper, or cardboard.
  • Allow proper ventilation while the internal battery is charging.
  • Never place the portable power unit directly above the battery being jump-started.
  • Position the unit as far from the battery as the cables allow.
  • Never allow the battery clamps to touch each other or the same metal surface.
  • Use only accessories recommended or sold by Schumacher Electric Corporation.

Vehicle Battery Restrictions

The jump-starting feature must only be used on vehicles, boats, and garden tractors equipped with a 12V DC battery system.

The FR01337 is intended for jump-starting lead-acid batteries.

Do not use the jump-starting function with household dry-cell batteries.

The portable power unit is not designed to replace a vehicle battery.

IMPORTANT: Do not use the jump starter on a vehicle that does not have a battery installed. Doing so can damage the vehicle’s electrical system.

Jump-Starting Safety

  • Never use the jump starter while its internal battery is charging.
  • Keep the cables away from fan blades, belts, pulleys, and moving engine components.
  • Do not allow sparks or flames near a vehicle battery.
  • Do not smoke near the battery or engine.
  • Disconnect the unit if the engine does not start after the recommended attempts.
  • Investigate other possible vehicle problems rather than continuing repeated jump-starting attempts.

Personal Safety Precautions

When working near lead-acid batteries:

  1. Wear complete eye protection.
  2. Wear protective clothing.
  3. Have another person nearby who can provide assistance.
  4. Keep clean water, soap, and baking soda available.
  5. Remove rings, bracelets, necklaces, watches, and other metal jewelry.
  6. Keep sparks and open flames away from the battery.

Battery Acid Safety

Battery acid can cause severe burns and eye injuries.

If battery acid contacts the skin or clothing, wash immediately with soap and water and obtain medical assistance.

If battery acid enters the eyes, flush immediately with water for at least 10 minutes and obtain medical attention.

Battery acid spills should be thoroughly neutralized with baking soda before cleanup.

Electrical Converter Safety

The built-in AC converter produces electrical power capable of causing serious electric shock.

  • Keep the portable power unit dry.
  • Do not operate the converter on wet surfaces.
  • Never operate the unit while hands or equipment are wet.
  • Keep the unit away from rain and moisture.
  • Do not modify the AC outlet.
  • Maintain sufficient ventilation.
  • Keep the unit away from heat sources and flammable fumes.
  • Do not exceed the converter’s 200W continuous power limit.

Life Support Equipment Restriction

The FR01337 must not be used to power life support devices or systems.

A failure of the converter could affect the safety or operation of such equipment.

Before First Use

The FR01337 must be charged before use to prepare its internal battery.

Initial Preparation

  1. Place the portable power unit on a stable, nonflammable surface.
  2. Inspect the power station for damage.
  3. Make sure the battery clamps are securely stored.
  4. Check the condition of the charging connection.
  5. Charge the internal battery completely.
  6. Press the Battery % button to verify the charge level.
  7. Disconnect the charging connection before using the jump-starting function.

IMPORTANT: Charge the internal battery immediately after purchase, after every use, and every 30 days while the unit is not in use.

This charging schedule helps keep the internal battery fully charged and prolong its service life.

How to Check the Internal Battery Charge Level

The digital display shows the percentage of charge remaining in the internal battery.

Checking Battery Percentage

  1. Disconnect the unit from connected electrical devices and charging sources.
  2. Press the Battery % button.
  3. Read the battery charge percentage shown on the digital display.
  4. Recharge the internal battery if the displayed charge is below 100%.

For the most accurate battery percentage reading, allow the unit to remain disconnected from devices and charging sources for a few hours before checking.

How to Charge the Internal Battery Using AC Power

The internal battery can be charged through the AC charging connection on the back of the unit.

An extension cord is required for this charging method.

Required Charging Equipment

ItemRequirement
Charging Source120V AC Electrical Outlet
Extension Cord18 AWG or Larger
Charging ConnectionRear AC Charging Connector
Maximum Charging DurationUp to 72 Hours
Charging ControlAutomatic Maintain Mode

AC Charging Instructions

  1. Locate the AC charging connector on the back of the unit.
  2. Flip the connector downward.
  3. Connect an 18 AWG or larger extension cord to the charging connector.
  4. Plug the extension cord into a 120V AC wall outlet.
  5. Watch the digital display for moving dashes that indicate charging.
  6. Allow the internal battery to charge completely.
  7. When charging is complete, the display shows a smaller pulsing ioo indication.
  8. The charger automatically switches to Maintain mode after the internal battery is fully charged.

Complete charging may take up to 72 hours.

Automatic Maintain Mode

Once the internal battery is fully charged, the charging system automatically switches to Maintain mode.

During Maintain mode:

  • The internal battery remains at full charge.
  • The Battery % LED pulses while AC power remains connected.
  • The charging system maintains the battery without damaging it.

Recharge the FR01337 as soon as possible after use.

How to Charge the Internal Battery While Driving

The FR01337 can also be charged from a vehicle’s 12V accessory outlet while driving.

This method requires an optional 12V port charging cable.

Required Accessory

AccessoryPart Number
12V Port Charging Cable94500109

Important Charging Warning

WARNING: Do not charge the internal battery using the 12V port charging cable for more than 30 minutes. Never leave the battery unattended during this charging method.

Charging for too long may cause the battery to overcharge and could result in an explosion, property damage, or personal injury.

Vehicle Charging Instructions

  1. Make sure the vehicle engine is running.
  2. Connect one end of the 12V port charging cable to the portable power unit’s 12V DC power outlet.
  3. Connect the other end to the vehicle’s 12V accessory outlet or cigarette lighter socket.
  4. Monitor the internal battery charge percentage using the Battery % button.
  5. Disconnect the charging cable when the internal battery is fully charged or before the 30-minute limit is reached.
  6. Remove the charging cable from the portable power unit first.
  7. Disconnect the cable from the vehicle accessory outlet.

Vehicle Charging Limitations

  • The Battery % LED does not operate during this charging method.
  • Automatic Maintain mode is bypassed.
  • The internal battery can become overcharged.
  • The charging cable must be disconnected completely when the vehicle engine is not running.

How to Jump Start a Vehicle

The FR01337 provides up to 1200 peak amps for jump-starting compatible 12V vehicle battery systems.

WARNING: The jump-starting feature must not be used while the internal battery is charging.

Before Jump-Starting

  1. Make sure the vehicle uses a 12V DC battery system.
  2. Confirm that a battery is installed in the vehicle.
  3. Turn the vehicle ignition OFF.
  4. Keep the jump starter ON/OFF switch in the OFF position.
  5. Position the cables away from fan blades, belts, pulleys, and other moving parts.
  6. Determine whether the vehicle uses a negative-ground or positive-ground electrical system.

Connecting to a Negative-Ground Vehicle

Most vehicles use a negative-ground electrical system.

  1. Connect the red positive clamp to the positive (+) battery terminal.
  2. Connect the black negative clamp to the vehicle chassis or engine block away from the battery.
  3. Make sure the clamps are securely attached.

Connecting to a Positive-Ground Vehicle

For a positive-ground electrical system:

  1. Connect the black negative clamp to the negative (–) battery terminal.
  2. Connect the red positive clamp to the vehicle chassis or engine block away from the battery.
  3. Confirm that the connections are secure.

Reverse-Polarity Audio Alarm

If the battery clamps are connected with reversed polarity, an audible alarm sounds.

Do not turn the jump starter switch ON while the reverse-polarity alarm is sounding.

Incorrect connections may seriously damage the vehicle or jump starter.

Disconnect the unit and correct the clamp connections. The alarm stops when the connections are corrected.

Starting the Engine

  1. After making the correct battery connections, turn the jump starter switch to ON.
  2. Attempt to start the engine.
  3. Crank the engine for no more than 8 seconds.
  4. If the engine does not start, wait 2 minutes before trying again.
  5. When the engine starts, turn the jump starter switch to OFF.
  6. Disconnect the portable power unit from the vehicle battery.
  7. Recharge the FR01337 after use.

If the engine does not start after the recommended attempts, disconnect the jump starter and check for other problems that may need correction.

How to Use the Flexible Work and Emergency Light

The FR01337 includes a flexible work light that can provide steady or flashing illumination.

Work Light Instructions

  1. Place the portable power unit on a flat, stable surface near the work area.
  2. Make sure the battery clamps are securely attached to their storage holders.
  3. Remove the flexible work light from its storage clip on the side of the unit.
  4. Point the light toward the intended area.
  5. Press the Flex Light button once to turn the light on.
  6. Press the button again to activate the flashing mode.
  7. Press the button a third time to turn the light off.
  8. Return the light to its storage clip after use.
  9. Recharge the portable power unit as soon as possible after using the light.

Important: Do not use the flexible light to lift or carry the power station.

Automatic Light Shutoff

The flexible work light automatically turns off after 24 hours.

How to Use the USB Charging Ports

The FR01337 has four USB ports for powering compatible USB devices.

Two ports on the left are optimized for Android devices, and two ports on the right are optimized for Apple devices.

USB Output Specifications

SpecificationDetails
Total USB Ports4
Left USB Ports2, Optimized for Android
Right USB Ports2, Optimized for Apple
USB Output Voltage5V DC
Maximum Output Per Side2A
Maximum Combined Output4A

USB Charging Instructions

  1. Make sure the battery clamps are securely clipped onto their storage holders.
  2. Connect the device to one of the four USB ports.
  3. Press the USB ON/OFF button.
  4. Turn on the connected USB device.
  5. When finished, press the USB button again to turn off the USB output.
  6. Recharge the portable power station as soon as possible after USB use.

USB Low-Battery Protection

The USB output automatically shuts off when the internal battery voltage becomes low.

This feature protects connected electronic devices.

How to Power a 12V DC Device

The FR01337 includes a 12V DC accessory power outlet rated for a maximum current of 20A.

It can supply power to compatible 12V accessories equipped with a standard 12V accessory plug.

12V DC Operating Instructions

  1. Make sure the connected 12V device is turned OFF.
  2. Check that the jump starter clamps are securely stored on their holders.
  3. Open the protective cover of the 12V DC outlet.
  4. Insert the device’s 12V accessory plug into the outlet.
  5. Turn on the connected 12V device if required.
  6. When finished, turn off the connected device.
  7. Remove the accessory plug from the DC outlet.
  8. Recharge the portable power unit immediately after use.

12V DC Power Limitations

CAUTION: Do not connect appliances that draw more than 20A DC.

Do not power a 12V DC accessory from the unit while the internal battery is charging.

Extended operation of 12V devices may significantly discharge the internal battery.

Estimated 12V DC Device Run Times

The following table provides estimated operating times based on a fully charged internal battery.

Device TypeEstimated Power ConsumptionEstimated Run Time
Cell Phone4W54 Hours
Fluorescent Light4W54 Hours
Radio or Fan9W24 Hours
Depth Finder9W24 Hours
Camcorder15W14.4 Hours
Electrical Tool24W9 Hours
Electric Cooler48W4.5 Hours
Car Vacuum or Air Compressor80W2.7 Hours

These values are estimates based on a fully charged internal battery.

Actual operating time may vary.

How to Use the Air Compressor

The Schumacher FR01337 includes an air compressor with a maximum pressure rating of 100 PSI.

The compressor uses adjustable pressure controls and automatically stops when the selected pressure is reached.

Air Compressor Safety

WARNING: Read the inflation instructions for the item being inflated. Never exceed the manufacturer’s recommended pressure.

  • Do not overinflate tires or other inflatable items.
  • Do not leave the compressor unattended during use.
  • Do not exceed 100 PSI.
  • Do not operate the compressor for more than 10 continuous minutes.
  • Allow the unit to cool for 10 minutes before using the compressor again.

Air Compressor Operating Instructions

  1. Remove the air compressor hose from the storage compartment at the back of the unit.
  2. Connect the hose adapter to the valve stem by threading it onto the valve.
  3. Use an additional inflation adapter if necessary.
  4. Press the Compressor button.
  5. Press the + or – buttons to select the desired pressure in PSI.
  6. Press the SET button to confirm the pressure setting.
  7. Allow the compressor to inflate the item.
  8. The compressor automatically stops when the selected pressure is reached.
  9. Unscrew the connector from the valve stem.
  10. Press the Compressor button again to turn off the display and LEDs.
  11. Return the compressor hose to the rear storage compartment.
  12. Allow the unit to cool.
  13. Recharge the unit before storing it.

Estimated Inflation Times

ItemEstimated Inflation Time
Vehicle Tires, 13–16 Inches6–24 Minutes
Bicycle Tires1–3 Minutes
Sports BallsApproximately 30 Seconds

These times are approximate. The compressor pressure gauge should be used to check that the correct pressure has been reached.

Compressor Operating Time Limit

The compressor must not run for more than 10 minutes continuously.

After 10 minutes of operation, allow the unit to cool for 10 minutes before using it again.

Compressor Overheat Protection

The air compressor includes built-in thermal protection.

If the compressor becomes too hot, the protection system shuts it off automatically.

After cooling for a few minutes, the compressor may restart automatically.

Automatic Compressor Shutoff

When the compressor is not in use, it automatically shuts off after approximately 2 minutes.

Before Using the AC Power Converter

The FR01337 includes a built-in power converter for operating compatible household AC devices.

AC Converter Specifications

SpecificationDetails
Rated AC Output120V AC, 60Hz
Continuous Power200W
Peak Power400W
Output WaveformModified Sine Wave
AC Outlet3-Prong NEMA 5-15
Recommended Maximum Device Load200W Continuous

The operating instructions refer to the household outlet as 110V AC, while the technical specifications identify its nominal rating as 120V AC.

Converter Safety Precautions

Before using the converter:

  1. Keep several inches of clearance around the top and sides of the unit.
  2. Do not block the ventilation openings at the back.
  3. Keep the unit away from flammable fumes and materials.
  4. Protect the unit from rain and moisture.
  5. Do not operate the converter on wet surfaces.
  6. Keep the unit away from heating vents, radiators, and other heat sources.
  7. Avoid direct sunlight.
  8. Do not operate the converter near an open engine compartment where fumes may accumulate.
  9. Do not modify the AC receptacle.

The recommended operating air temperature is 50°F to 80°F.

AC Power Converter Limits and Compatibility

The built-in converter is designed for devices drawing 200W or less of continuous power.

If the device does not display a wattage rating, the manual instructs using only devices drawing less than 1.7A of AC current.

Starting and Peak Power

Some appliances, such as fans, televisions, and electrical motors, require additional power during startup.

Even if a device is rated below 200W during normal operation, its starting current may exceed the converter’s surge capability.

This can cause the converter to shut down automatically.

Modified Sine Wave Compatibility

The FR01337 uses a modified sine wave converter.

Its output waveform is different from standard utility-supplied AC power.

The manufacturer recommends checking compatibility before operating the following devices:

  • Switch-mode power supplies.
  • Linear power supplies.
  • Class 2 transformers.
  • Line filter capacitors.
  • Shaded-pole motors.
  • Fan motors.
  • Fluorescent and high-intensity lamps with ballasts.
  • Transformerless battery chargers.

Some devices may operate at higher temperatures or overheat when powered by the converter.

Using Battery Chargers with the Converter

If a battery charger is powered through the FR01337 AC outlet:

  1. Monitor the battery charger’s temperature for approximately 10 minutes.
  2. If the battery charger becomes unusually warm, disconnect it from the converter immediately.

Extension Cord Requirements for the AC Converter

An extension cord can be connected between the converter outlet and the electrical device.

For best results, the extension cord should meet the following specifications:

RequirementSpecification
Minimum Wire Size16 AWG
Maximum Length50 Feet

How to Power an AC Device

The FR01337 can supply AC power to compatible electrical devices through its built-in converter.

AC Power Operating Instructions

  1. Make sure the battery clamps are securely stored on their holders.
  2. Open the protective cover of the AC outlet on the front panel.
  3. Make sure the connected AC device is turned OFF.
  4. Connect the device’s plug to the AC outlet.
  5. Press the Converter button.
  6. Turn on the connected electrical device.
  7. Recharge the portable power unit as soon as possible after use.

Important AC Power Limit

Do not connect appliances that draw more than 200W of continuous power.

Exceeding this limit may damage the converter or the connected device.

Automatic Overload Protection

If the connected device draws excessive power, the converter is designed to shut down automatically.

This prevents damage during overload conditions.

The converter may also display err when the internal battery is not fully charged or the connected device exceeds the supported power limit or has a short circuit.

Digital Display Messages and Operating Indicators

The FR01337 uses its digital display, LED indicators, and audible alarm to communicate operating conditions.

Display and Indicator Meanings

Display or IndicatorMeaningRecommended Action
Battery PercentageInternal battery charge levelRecharge if below 100%
Moving DashesInternal battery charging through AC powerAllow charging to continue
Small Pulsing iooInternal battery fully chargedAutomatic Maintain mode begins
Battery % LED PulsingAC charging system is in Maintain modeNormal operation
Vehicle Battery VoltageJump starter connected with switch OFFVehicle battery voltage is being displayed
Equalized VoltageJump starter connected with switch ONDisplays equalized voltage
Reverse-Polarity Audio AlarmBattery clamps connected incorrectlyKeep switch OFF and correct connections
errConverter fault involving battery charge, overload, or short circuitRecharge the unit or check the connected device

Maintenance and Cleaning Instructions

Regular maintenance helps protect the unit’s electrical connections and internal battery.

Cleaning the Battery Clamps

After using the jump starter:

  1. Make sure the jump-starting function is switched OFF.
  2. Disconnect the clamps from the vehicle.
  3. Clean the clamps.
  4. Return the clamps to their storage holders.

Cleaning the Housing

Clean the portable power unit’s housing after use.

Battery Maintenance

The internal battery should be kept charged.

  • Recharge immediately after purchase.
  • Recharge after every use.
  • Recharge every 30 days when the unit is not being used.
  • Never allow the internal battery to become completely discharged.

Battery Clamp Storage

Store the battery clamps on their support posts.

This prevents the clamps from contacting each other or another metal surface.

Storage Instructions

The FR01337 should be stored with its internal battery charged and its accessories properly secured.

Storage Procedure

  1. Recharge the internal battery.
  2. Clean the housing and battery clamps.
  3. Return the clamps to their storage holders.
  4. Return the compressor hose to its rear storage compartment.
  5. Return the flexible work light to its storage clip.
  6. Keep the unit protected from moisture and excessive heat.
  7. Recharge the unit every 30 days while it is stored.

Never completely discharge the internal battery.

Troubleshooting Guide

The Schumacher FR01337 troubleshooting instructions cover jump-starting problems, 12V accessory power failures, compressor shutdowns, battery charging problems, reverse-polarity alarms, and converter errors.

Schumacher FR01337 Troubleshooting Table

ProblemPossible CauseRecommended Solution
Jump starter will not start the vehicleClamps are not making proper contactCheck connections to the battery and vehicle frame; clean the connection points
Jump starter will not start the vehicleBattery clamp connections are reversedDisconnect the unit and correct the connections
Jump starter will not start the vehicleInternal battery is not chargedCheck the charge level using the Battery % button
Jump starter will not start the vehicleVehicle battery is defectiveHave the vehicle battery checked
Jump starter will not start the vehicleJump starter switch is OFFTurn the switch ON after making correct connections
12V DC device does not operateConnected device is OFFTurn on the connected device
12V DC device does not operateInternal battery is dischargedCheck the internal battery charge level
12V DC device does not operateDevice draws more than 20A, has a short circuit, or internal fuse has blownDisconnect the device; have the internal 20A fuse replaced by qualified service personnel if necessary
Internal battery will not hold a chargeInternal battery is defectiveHave the battery checked
Air compressor stopsCompressor overheatedAllow the compressor to cool for a few minutes
Audio alarm soundsBattery clamps are connected with reversed polarityDisconnect the unit and correct the clamp connections
Converter displays errInternal battery is not fully chargedRecharge the portable power unit
Converter displays errConnected device draws more than 200W or has a short circuitUse a device drawing less than 1.7A AC current and within the converter’s power rating

FR01337 Will Not Jump Start a Vehicle

If the jump starter does not start the engine, several conditions may need to be checked.

Poor Battery Clamp Connections

Check the clamps connected to the vehicle battery and chassis.

Make sure both connection points are clean and the clamps are secure.

Reversed Battery Clamp Connections

If the clamps are connected incorrectly, disconnect the jump starter and reverse the connections.

Low Internal Battery Charge

Press the Battery % button to check the internal battery.

Recharge the unit if necessary.

Defective Vehicle Battery

If the battery connections and internal battery charge are correct, have the vehicle battery checked.

Jump Starter Switch OFF

The ON/OFF switch must be in the ON position during the jump-starting attempt.

The switch should only be turned ON after the battery clamps are correctly connected.

FR01337 Will Not Power a 12V Device

If the connected 12V device does not operate:

  1. Check whether the connected device is switched ON.
  2. Check the internal battery charge level.
  3. Confirm that the connected device does not exceed 20A.
  4. Disconnect the device if an overload or short circuit is suspected.

If the internal 20A fuse has blown, it must be replaced by a qualified service professional.

FR01337 Internal Battery Will Not Hold a Charge

If the internal battery does not retain its charge, it may be defective or unable to accept charging current.

Have the internal battery checked.

FR01337 Air Compressor Keeps Shutting Off

The compressor includes thermal protection that automatically shuts off the motor if it overheats.

Allow the compressor to cool for a few minutes before trying again.

The compressor should not be operated for more than 10 minutes continuously. Allow 10 minutes of cooling time between operating periods.

FR01337 Reverse-Polarity Alarm Is Sounding

An audible alarm indicates reversed battery clamp connections.

Correcting the Connections

  1. Keep the jump starter ON/OFF switch in the OFF position.
  2. Disconnect the jump starter from the vehicle battery.
  3. Correct the clamp connections.
  4. Confirm that the alarm has stopped before operating the jump starter.

Do not switch the jump starter ON while the reverse-polarity alarm is active.

FR01337 Converter Shows ERR

The digital display may show err while the AC converter is activated.

Possible Causes

  • The internal battery is not fully charged.
  • The connected AC device draws more than 200W.
  • The connected device has a short circuit.

Troubleshooting Steps

  1. Recharge the internal battery.
  2. Check the connected device’s power requirements.
  3. Use only compatible devices within the converter’s 200W continuous power limit.
  4. If the device does not have a wattage rating, use only devices drawing less than 1.7A of AC current.

Accessories and Replacement Parts

Schumacher identifies the following accessory and replacement part numbers for the FR01337.

Accessories

AccessoryPart Number
12V Port Charging Cable94500109

The 12V charging cable is an optional accessory and is not included with the portable power unit.

Replacement Parts

Replacement PartPart Number
Air Compressor Accessory Kit – 3 Hose Adapters with Bag2299001425Z
Battery Clamp Replacement Kit – 1 Red Positive Clamp and 1 Black Negative Clamp2299002837Z

Internal Battery Disposal

The Schumacher FR01337 contains a sealed, non-spillable lead-acid battery.

The battery must be disposed of properly.

Battery acid can cause severe burns and blindness, and the battery presents a potential explosion hazard.

Keep the battery and power station away from children.

Limited Warranty

Schumacher Electric Corporation provides separate warranty coverage for the FR01337 portable power unit and its internal battery.

Warranty Coverage

Warranty DetailInformation
ManufacturerSchumacher Electric Corporation
Product Warranty1 Year
Internal Battery Warranty90 Days
Warranty Start DateDate of Retail Purchase
Eligible PurchaserOriginal Retail Purchaser
TransferabilityNot Transferable
Covered DefectsDefective Materials or Workmanship Under Normal Use and Care

Warranty Repair or Replacement

If the product develops a covered defect during the warranty period, Schumacher may repair or replace it with a new or reconditioned unit.

The manufacturer determines whether repair or replacement is appropriate.

The purchaser must provide proof of purchase and pay the shipping charges in advance when sending the product to Schumacher or its authorized representatives.

Warranty Exclusions

The limited warranty may be void if the product:

  • Is misused.
  • Is handled carelessly.
  • Is repaired or modified by someone other than the manufacturer.
  • Is resold through an unauthorized retailer.
  • Has a warranty label removed when the manufacturer determines that its removal voids coverage.

Accessories not manufactured and approved by Schumacher Electric Corporation are excluded from warranty coverage.

The warranty also contains limitations relating to other warranties and incidental or consequential damages. Applicable rights may vary by state.

Warranty Registration

Warranty registration is available through:

www.batterychargers.com

The warranty registration card should be submitted within 30 days of purchase.

The original retail receipt must be retained for warranty claims.

Customer Support and Repair Information

Schumacher Electric Corporation provides customer support for operating problems, troubleshooting, repairs, and product returns.

Customer Support Details

ServiceContact Information
ManufacturerSchumacher Electric Corporation
Support Phone1-800-621-5485
Support Emailservices@schumacherelectric.com
Website Listed in Manualwww.batterychargers.com
Support Hours Listed in ManualMonday–Friday, 7:00 AM–5:00 PM CST
Manufacturer Address801 Business Center Drive, Mount Prospect, IL 60056-2179

Repair and Return Instructions

  1. Review the troubleshooting instructions.
  2. Contact Schumacher Customer Service if the issue continues.
  3. Describe the operating problem.
  4. Follow the manufacturer’s support instructions.
  5. Request a Return Merchandise Authorization (RMA) number if repair or return is required.
  6. Do not ship the unit until Schumacher has issued an RMA number.

Important: Do not send the portable power unit to the warranty registration address for repairs.

Frequently Asked Questions

1. How do I charge the Schumacher FR01337 jump starter?

The FR01337 internal battery is charged through the rear AC charging connector using an 18 AWG or larger extension cord connected to a 120V AC outlet. Moving dashes appear on the digital display during charging, and a small pulsing ioo appears when the battery is fully charged. Complete charging may take up to 72 hours.

2. How many amps does the Schumacher FR01337 provide for jump-starting?

The Schumacher FR01337 provides 1200 peak amps for jump-starting compatible vehicles with 12V DC lead-acid battery systems. It must not be used without a battery installed in the vehicle.

3. How do I jump start a car with the Schumacher FR01337?

With the jump starter switch OFF, connect the battery clamps using the correct vehicle grounding procedure. Turn the jump starter ON and crank the engine for no more than 8 seconds. If the engine does not start, wait 2 minutes before trying again. After starting, turn the unit OFF, disconnect the clamps, and recharge the portable power station.

4. How often should the Schumacher FR01337 be charged?

The FR01337 should be charged immediately after purchase, after every use, and every 30 days when it is not being used. The internal AGM lead-acid battery should never be allowed to become completely discharged.

5. What is the maximum air pressure of the Schumacher FR01337 compressor?

The built-in air compressor has a maximum pressure rating of 100 PSI. The desired pressure can be selected using the + and – buttons and confirmed with SET. The compressor automatically stops when the selected pressure is reached. It must not run for more than 10 minutes continuously, followed by 10 minutes of cooling.

6. Can the Schumacher FR01337 power household electrical devices?

Yes. The FR01337 includes a modified sine wave AC converter rated for 200W continuous power and 400W peak power. Connected devices must be compatible with modified sine wave output and remain within the converter’s power limits.

7. Why does the Schumacher FR01337 display ERR?

The err display indicates a converter problem that may be caused by a low internal battery charge, a connected device drawing more than 200W, or a short circuit in the connected device. Recharge the unit and check the device’s power requirements before further use.

8. What does the alarm mean on the Schumacher FR01337?

The audible alarm indicates that the jump-starting clamps are connected with reversed polarity. Keep the jump starter switch OFF, disconnect the clamps, and correct the connections. The alarm stops when the connections are corrected.